Jim,
Is the HMDS prime vacuum vapor prime. The vacuum dehydration removes
moisture, HMDS reacts with moisture leaving molecular sights that can lift
causing poor adhesion. Bill Moffat
-----Original Message-----
From: Jim Beall [mailto:[email protected]]
Sent: Tuesday, May 13, 2003 1:50 PM
To: [email protected]
Subject: [mems-talk] photoresist adhesion to Tungsten
Dear All -
A colleague is using photoresist and a hydrogen peroxide wet etch to
pattern 200 nm thick W films. He is having adhesion problems for
etches longer than 30 seconds (large areas of PR peel off). He has
tried HMDS prime, 120 C post bake, etc. The post bake helped a
little, but he needs a more durable coat.
Does anyone have any lore for increasing PR adhesion to W in a
hydrogen eroxide etch?