PSG etch rate in 10:1 HF is depended on how PSG being deposited and any
post deposition densify anneal was carried out. Undensified PSG can have
etch rate 5-10 times higher than that of thermal SiO2. Densified PSG (850C
and up for 30 minutes in O2) has etch rate 1.5-2 times higher usually.
But any rate is not even near what your 15 seconds. For 1.8um, at least
1-2
minutes is needed to strip all in 10:1 HF for undensified PSG.
Hong Wu
-----Original Message-----
From: [email protected]
[mailto:[email protected]]On Behalf Of Paul
Vescovo
Sent: 2004Äê3ÔÂ19ÈÕ 3:11
To: [email protected]
Subject: [mems-talk] PSG etch rate in HF:H2O
Dear all,
There is a critical flaw on devices I worked out recently.
A possible explanation for it is the complete etching of 1.8um of PSG (6%P)
during a RCA (15s in HF(49%):H2O 1:10 at 20°C).
Is this hypothesis sensible ?
Thank you,
paul