Shay,
Cr diffuses into Au easily specially at 370 C and above temperatures. The
alloy has a higher resistivity. You can add a layer of Pt (300-400 A) in
between Cr and Au to prevent diffusion. Or consider using Ti or TiW
instead of Cr if your process permits.
Good luck,
Zhimin
Shay Kaplan
To:
Sent by: cc:
mems-talk-bounces@ Subject: [mems-talk] metal
resistance after anodic bonding
memsnet.org
07/15/2004 07:08
AM
Please respond to
General MEMS
discussion
Hi,
We have been using Cr/Au 1500/2500 evaporated conductors on Pyrex for
devices that are latter anodicaly
bonded.
We have noticed a 10 fold increase in resistance following exposure to 370
deg for 30 min at nitrogen
ambient.
analysis showed that the chrome only does not change it's resistance.
anybody out there know what is causing this? any idea how to avoid it?
better two metal option?
thanks
shay
_______________________________________________
[email protected] mailing list: to unsubscribe or change your list
options, visit http://mail.mems-exchange.org/mailman/listinfo/mems-talk
Hosted by the MEMS Exchange, providers of MEMS processing services.
Visit us at http://www.memsnet.org/