How about oxygen plasma plus a little bit of CF4 to make the
plasma etch more aggressive?
Patrick Cheung, research scientist Xerox PARC, MS 35-1674
(O) 650-812-4338 (FAX) 650-812-4334 3333 Coyote Hill Road
[email protected] Palo Alto, CA 94304
>> >>
>> >>
On Wed, 18 Feb 1998, Sergio Palma Pacheco wrote:
I am using cured polyimide (PI 2545) as a sacrificial layer in a process
to
create long and wide airbridges. I have been using hot (110C)
Ethylenediamine
to etch the polyimide, but it does not seem to remove all of the
material
underneath the bridges. I have included holes to facilitate the
diffusion of the
etchant under the bridges as well as a stirrer, but to no avail. Does
anyone
know of other etchants that could be used to remove the polyimide;
especially
underneath the bridges? By the way, the bridges are made of chrome and
electroplated gold. Therefore, the etchants cannot attack these metals.
Thanks,
Sergio
--
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
._,
,_| |._/\ Sergio Palma Pacheco
| |o/^^~-._ Radiation Laboratory
/-' | ~ 3121 EECS Building
\__/|_ /' University of Michigan
\__ | . Ann Arbor, MI 48109
| __/'
> /' Tel: (313) 936-2975
/' /' Fax: (313) 747-2106
~~^\/' e-mail: [email protected]
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*