Hello,
For the micro fabricated bio chip/ micro fluidic devices Class 1000/100
required, although it is dependent on the fabrication protocol and
materials as well as dimension. Usually polymer based micro fluidic
devices demand class 1000/100 for the fabrication. For the cleaning you
can use Decon 90 and followed by IPA in the ultrasonic bath. It will
remove micro/nano monomer.
Regards,
Mamun Rashid
PhD Candidate
Centre for Nano & Microsystems
University of Teesside
TS1 3BA. U.K
www.mamun.info