Adhesion problem during 7740 glass wafer wet etching process
Shay Kaplan
2010-12-13
Try evaporate CrAU or magnetron sputtered CrAu. With 48% HF
-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Xin Yan
Sent: Monday, December 13, 2010 2:50 PM
To: [email protected]
Subject: [mems-talk] Adhesion problem during 7740 glass wafer wet etching
process
Hi everyone,
i want to etch the 7740 about 4 to 20 um deep. Using Cr with Photoresist
5214E as the mask, Cr layer was produced by DC sputtering about 200nm
thick. The etchant is 1 HF : 2 HNO3 : 2 H2O to get high etch rate about
2um/min to the 7740.
we met a problem that Cr can not stand in this solution even 2minutes.
After about 2 min, Cr begin to peel off.
In the 49%HF without HNO3, Cr cannot stand even 1minutes.
what cause the Cr so unstable or it is supposed to be like this? or i need
to change the etchant ?
Thank you
Yan Xin