I believe the metal pattern peeled off all together from the quartz substrate.
And for your reference, my current density is pretty low, around 1
mA/cm2, and I need a thickness of 5um, so I plated for about one and a
half hour. Is it possible that putting the sample in the warm
electrolyte for that long would cause lamination?
Thanks!
Sheng
On Fri, Mar 11, 2011 at 01:56, David Roberts
wrote:
> Hi Sheng,
>
> You need to include one important piece of information.
> What is the interface that the adhesion failed?
> When you peel back the gold what material is on the back?
>
> Regards,
> Dave