The fault may be with the bonding unit. I have several customers doing Silicon
Wafer to Silicon wafer bonding using about 10 minutes plasma no heat. Others
doing a flexible polymer to glass with a 20 second plasma no heat, contact me
for further information. Bill Moffat
-----Original Message-----
From: [email protected] [mailto:mems-
[email protected]] On Behalf Of ???
Sent: Tuesday, August 16, 2011 1:19 AM
To: [email protected]
Subject: [mems-talk] Glass-glass bonding problem
Dear everyone:
Does anyone who has the available process to do the glass-glass bonding?
I have tried several times with the glass-glass bonding, and I have used
RCA1# solution and O2 plasma activation for assistant, but finally I can't
realize the bonding.
The process temperature is about 200~300 ℃ ,and the bonding pressure is about
2000N, 6' Pyrex7740 glass wafer, 500um thickness. The bonding machine is
EVG520.
Thanks to any help.
Regards.
Evan J