following situations may be true:
1. the mask you prepared if by (wet etching ) might have different
dimensions than conceived in design.
2. you are under etching after exposure, in that increase time for etching
in SU8 developer.
3. you have a heating process after etching.
On Mon, Jul 28, 2014 at 12:58 PM, Janis Klavins
wrote:
> Hello all,
>
> I have a strange problem with SU8 structures. When we expose and develop
> the structure it is wider than necessary in SEM image it is possible to see
> that those wider areas are somehow different and the side of the structure
> is "fluffy" not straight and even. (see the image below.
> I believe it might be one of the following:
> 1) Over-exposure: I cannot change exposure time due to additional adhesion
> problems
> 2) Mask is in proximity instead of contact mode: thickness of coating
> varies by 1 um (I do not think that it should make such a problem)
> 3) Something wrong in Post-exposure (too long or too hot)
>
> Does anyone with greater experience with SU8 could suggest anything?
>
>
> --
> Best regards,
> Mr. Janis Klavins
> EuroLCDs
> Phone: +37163600300
> Mobile: +37126141049
>
> _______________________________________________
> Hosted by the MEMS and Nanotechnology Exchange, the country's leading
> provider of MEMS and Nanotechnology design and fabrication services.
> Visit us at http://www.mems-exchange.org
>
> Want to advertise to this community? See http://www.memsnet.org
>
> To unsubscribe:
> http://mail.mems-exchange.org/mailman/listinfo/mems-talk
>
_______________________________________________
Hosted by the MEMS and Nanotechnology Exchange, the country's leading
provider of MEMS and Nanotechnology design and fabrication services.
Visit us at http://www.mems-exchange.org
Want to advertise to this community? See http://www.memsnet.org
To unsubscribe:
http://mail.mems-exchange.org/mailman/listinfo/mems-talk