RE: Contamination issue of additive in THAH etching
gracekuo
2002-08-19
Hi Philipe and Mike,
thank you for your reply,
let me describe the contamination more specific,
after we add the AP (2.5g dissolved in DI water, add
into the etchant per 15 min. )
into the heated etchant (2L ; include TMAH, AP, SA,
and DI water),
we can see white particulates float over the etchant
immediately,
the particulate size is quite big (~2x1x1 cm3),
and it can dissolve into the etchant after 10~15min.
And after the etching, we just clean the sample with
DI water,
but as we observe the etched sample,
there are plenty of particles over the sample surface,
and the particulates is especially big stored in
etched cavity,
as we analysis the particle with EDAX, it just have Si
and O composition,
i dont know if it is just the silicic acid that
precipitated out of solution,
and could anyone give us some suggestion to prevent
this particulates,
thank you for your help,
grace
Email:[email protected]
-----------------------------------------------------------------
< (C$Q3# Yahoo!)_ > www.yahoo.com.tw