One widely used technique is direct laser ablation using a KrF excimer
at 248 nm. We used this technique to produce via's from 25-1000 microns
in electroplated polyimide radiation detectors. You should be aware that
the cost of ownership on these systems are quite high. Also, if you want
to machine holes over a large area, say larger than a few square cm this
may not be the solution for you. Here's some companies that will quote a
system for you:
www.lambdaphysik.com and www.jpsalaser.com
-Mike
>>> [email protected] 12/10/02 09:15AM >>>
Dear all,
I'm searching information about the different technical possibilities
to
cut holes of 200 micron diameter in Kapton film.
The profile of the material must keep a good quality.
Any input is appreciated.
Regards,
Lucia Beccai
--
----------------------------------------------
Lucia Beccai
CRIM Lab
Polo Sant'Anna Valdera
Scuola Superiore Sant'Anna
Viale Rinaldo Piaggio 34 - 56025 -Pontedera (Pisa) - Italy
phone: +39 050 883 488
fax +39 050 883 402
http://www-crim.sssup.it/
_______________________________________________
[email protected] mailing list: to unsubscribe or change your list
options, visit http://mail.mems-exchange.org/mailman/listinfo/mems-talk