In my experience dealing with thick SU-8 layers I saw less cracking if I
slowed down the rate of development. Try diluting your developer.
Jennifer Pagan
Senior Process Engineer
WaveguideSolutions, Inc.
[email protected]
Phone: 704-927-0408
Fax: 704-599-3536
-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Yoon Seung Wook
Sent: Thursday, March 13, 2003 3:00 AM
To: [email protected]
Subject: [mems-talk] Question on crack during SU-8 developing
Dear Members,
I found some cracking issue during SU-8 developing process.
Crack was found at corner area. Our via is square and size is
4mmx4mm.(it is very big)
So it is very hard to control the crack or delamination.
Please share your experience on this issue.
I'm looking forward to hearing your suggestion or recommendation on
SU-8.
Thanks in advance.
------------------------------------------------------------------------
Seung Wook (Uk) , YOON Ph.D
Senior Research Engineer
MMII, MMC Lab
Institute of Microelectronics (IME)
A-Star, Singapore
11Scenence Park Road,
Science Part II, Singapore 117685
Phone (Office) 65-6770-5442
Fax (Office) 65-6774-5747